Journal Description
Instruments
Instruments
is an international, peer-reviewed, open access journal on scientific instrumentation and its related methods and theory, published quarterly online by MDPI.
- Open Access— free for readers, with article processing charges (APC) paid by authors or their institutions.
- High Visibility: indexed within Scopus, Inspec, CAPlus / SciFinder, INSPIRE, and other databases.
- Rapid Publication: manuscripts are peer-reviewed and a first decision is provided to authors approximately 32.1 days after submission; acceptance to publication is undertaken in 7.3 days (median values for papers published in this journal in the first half of 2023).
- Recognition of Reviewers: reviewers who provide timely, thorough peer-review reports receive vouchers entitling them to a discount on the APC of their next publication in any MDPI journal, in appreciation of the work done.
Latest Articles
Design of Monolithic Bi-Layer High-Z PAL-Si Hard X-ray CMOS Image Sensors for Quantum Efficiency Enhancement
Instruments 2023, 7(3), 24; https://doi.org/10.3390/instruments7030024 - 28 Aug 2023
Abstract
►
Show Figures
This article experimentally investigates the inception of an innovative hard X-ray photon energy attenuation layer (PAL) to advance high-energy X-ray detection (20–50 keV). A bi-layer design with a thin film high-Z PAL on the top and Si image sensor on the bottom has
[...] Read more.
This article experimentally investigates the inception of an innovative hard X-ray photon energy attenuation layer (PAL) to advance high-energy X-ray detection (20–50 keV). A bi-layer design with a thin film high-Z PAL on the top and Si image sensor on the bottom has previously demon-strated quantum yield enhancement via computational methods by the principle of photon energy down conversion (PEDC), where high-energy X-ray photon energies are attenuated via inelastic scattering down to ≤10 keV, which is suitable for efficient photoelectric absorption by Si. Quantum yield enhancement has been experimentally confirmed via a preliminary demonstration using PAL-integrated Si-based CMOS image sensors (Si CIS). Furthermore, substituting the high-Z PAL with a lower-Z material—Sn—and alternatively coupling it with a conventional scintillator ma-terial—Lutetium-yttrium oxyorthosilicate (LYSO)—have been compared to demonstrate the most prominent efficacy of monolithic integration of high-Z PAL on Si CIS to detect hard X-rays, paving the way for next-generation high-energy X-ray detection methods.
Full article
Open AccessArticle
Utilization of Additive Manufacturing for the Rapid Prototyping of C-Band Radiofrequency Loads
by
, , , , , , and
Instruments 2023, 7(3), 23; https://doi.org/10.3390/instruments7030023 - 23 Aug 2023
Abstract
Additive manufacturing is a versatile technique that shows promise in providing quick and dynamic manufacturing for complex engineering problems. Research has been ongoing into the use of additive manufacturing for potential applications in radiofrequency (RF) component technologies. Here, we present a method for
[...] Read more.
Additive manufacturing is a versatile technique that shows promise in providing quick and dynamic manufacturing for complex engineering problems. Research has been ongoing into the use of additive manufacturing for potential applications in radiofrequency (RF) component technologies. Here, we present a method for developing an effective prototype load produced from 316L stainless steel on a direct metal laser sintering machine. The model was tested using simulation software to verify the validity of the design. The load structure was manufactured by an online digital manufacturing company, showing the viability of using easily accessible tools to manufacture RF structures. The produced load was able to produce an S value of −22.8 dB at a C-band frequency of 5.712 GHz while under a vacuum. In a high-power test, the load was able to terminate a peak power of 8.1 MW. The discussion includes future applications of the present method and how it will help to improve the implementation of future accelerator concepts.
Full article
(This article belongs to the Special Issue Microwave Measurements, Methods and Instruments for Science, Society and Industry)
►▼
Show Figures
Figure 1
Open AccessFeature PaperArticle
Additive Manufacturing of an IH-Type Linac Structure from Stainless Steel and Pure Copper
Instruments 2023, 7(3), 22; https://doi.org/10.3390/instruments7030022 - 07 Aug 2023
Abstract
►▼
Show Figures
Additive manufacturing (AM) of metals has the potential to provide significant benefits for the construction of future particle accelerators. The combination of low cost manufacturing of complex geometries in combination with efficiency gains from improved linac design enabled by AM may be one
[...] Read more.
Additive manufacturing (AM) of metals has the potential to provide significant benefits for the construction of future particle accelerators. The combination of low cost manufacturing of complex geometries in combination with efficiency gains from improved linac design enabled by AM may be one way towards future cost-effective green accelerator facilities. As a proof of concept, we present a high-efficiency , MHz IH-DTL cavity based on an AM design. In this case, the complex internal drift tube structures with internal cooling channels have been produced from 1.4404 stainless steel and from pure copper using AM. The prototype cavity, as well as stainless steel AM parts have been electroplated with copper. We present results from successful vacuum tests, low level RF measurements of the cavity, as well as the status of preparations for high-power RF tests with a 30 kW pulsed power amplifier.
Full article
Figure 1
Open AccessArticle
Analysis of Vector-Network-Analyzer-Based Power Sensor Calibration Method Application
by
, , , , , and
Instruments 2023, 7(3), 21; https://doi.org/10.3390/instruments7030021 - 19 Jul 2023
Abstract
Radio Frequency (RF) power sensor calibration is one of the essential measurements in RF and microwave metrology. For a reliable and accurate power sensor calibration, there are various methods, such as the substitution method, the direct comparison transfer method (DCTM), and the vector
[...] Read more.
Radio Frequency (RF) power sensor calibration is one of the essential measurements in RF and microwave metrology. For a reliable and accurate power sensor calibration, there are various methods, such as the substitution method, the direct comparison transfer method (DCTM), and the vector network analyzer (VNA)-based calibration method (VBCM). The VBCM is a method that is derived from the DCTM. It is a preferred method since the VNA has a better measurement capability and has fewer connection requirements for measurement devices. In this study, the milestones and potential application errors of the VBCM are given by considering the connection mistakes, measurement faults, calculation errors, and control software coding problems. At the end of the power sensor calibration measurements with the VBCM, the model function components and the uncertainty calculation examples according to the GUM Bayesian method are also presented in this study. In addition, the advantages and disadvantages of the VBCM compared to the former methods are discussed in this study.
Full article
(This article belongs to the Special Issue Microwave Measurements, Methods and Instruments for Science, Society and Industry)
►▼
Show Figures
Figure 1
Open AccessArticle
Inkjet-Printed Interdigitated Capacitors for Sensing Applications: Temperature-Dependent Electrical Characterization at Cryogenic Temperatures down to 20 K
by
, , , , , and
Instruments 2023, 7(3), 20; https://doi.org/10.3390/instruments7030020 - 19 Jul 2023
Abstract
Microwave transducers are widely used for sensing applications in areas such as gas sensing and microfluidics. Inkjet printing technology has been proposed as a promising method for fabricating such devices due to its capability to produce complex patterns and geometries with high precision.
[...] Read more.
Microwave transducers are widely used for sensing applications in areas such as gas sensing and microfluidics. Inkjet printing technology has been proposed as a promising method for fabricating such devices due to its capability to produce complex patterns and geometries with high precision. In this work, the temperature-dependent electrical properties of an inkjet-printed single-port interdigitated capacitor (IDC) were investigated at cryogenic temperatures down to 20 K. The IDC was designed and fabricated using inkjet printing technology, while its reflection coefficient was measured using a vector network analyzer in a cryogenic measurement setup and then transformed into the corresponding admittance. The resonant frequency and quality factor (Q-factor) of the IDC were extracted as functions of the temperature and their sensitivity was evaluated. The results showed that the resonant frequency shifted to higher frequencies as the temperature was reduced, while the Q-factor increased as the temperature decreased. The trends and observations in the temperature-dependent electrical properties of the IDC are discussed and analyzed in this paper, and are expected to be useful in future advancement of the design and optimization of inkjet-printed microwave transducers for sensing applications and cryogenic electronics.
Full article
(This article belongs to the Special Issue Microwave Measurements, Methods and Instruments for Science, Society and Industry)
►▼
Show Figures
Figure 1
Open AccessCorrection
Correction: Treffert et al. Towards High-Repetition-Rate Fast Neutron Sources Using Novel Enabling Technologies. Instruments 2021, 5, 38
by
, , , , , , , , and
Instruments 2023, 7(3), 19; https://doi.org/10.3390/instruments7030019 - 07 Jul 2023
Abstract
►▼
Show Figures
In the original publication [...]
Full article
Figure 1
Open AccessFeature PaperArticle
Investigating Slit-Collimator-Produced Carbon Ion Minibeams with High-Resolution CMOS Sensors
by
, , , , , and
Instruments 2023, 7(2), 18; https://doi.org/10.3390/instruments7020018 - 06 Jun 2023
Abstract
Particle minibeam therapy has demonstrated the potential for better healthy tissue sparing due to spatial fractionation of the delivered dose. Especially for heavy ions, the spatial fractionation could enhance the already favorable differential biological effectiveness at the target and the entrance region. Moreover,
[...] Read more.
Particle minibeam therapy has demonstrated the potential for better healthy tissue sparing due to spatial fractionation of the delivered dose. Especially for heavy ions, the spatial fractionation could enhance the already favorable differential biological effectiveness at the target and the entrance region. Moreover, spatial fractionation could even be a viable option for bringing ions heavier than carbon back into patient application. To understand the effect of minibeam therapy, however, requires careful conduction of pre-clinical experiments, for which precise knowledge of the minibeam characteristics is crucial. This work introduces the use of high-spatial-resolution CMOS sensors to characterize collimator-produced carbon ion minibeams in terms of lateral fluence distribution, secondary fragments, track-averaged linear energy transfer distribution, and collimator alignment. Additional simulations were performed to further analyze the parameter space of the carbon ion minibeams in terms of beam characteristics, collimator positioning, and collimator manufacturing accuracy. Finally, a new concept for reducing the neutron dose to the patient by means of an additional neutron shield added to the collimator setup is proposed and validated in simulation. The carbon ion minibeam collimator characterized in this work is used in ongoing pre-clinical experiments on heavy ion minibeam therapy at the GSI.
Full article
(This article belongs to the Special Issue Medical Applications of Particle Physics)
►▼
Show Figures
Figure 1
Open AccessArticle
Geant4 Simulation of Muon Absorption in Concrete Layers
by
and
Instruments 2023, 7(2), 17; https://doi.org/10.3390/instruments7020017 - 31 May 2023
Abstract
Muography requires a detailed understanding of the absorption of muons in the material situated between the muon source and the detector. A large-statistics (>3 billion event) Geant4 simulation was run to simulate the absorption of muons in different thicknesses of concrete layers and
[...] Read more.
Muography requires a detailed understanding of the absorption of muons in the material situated between the muon source and the detector. A large-statistics (>3 billion event) Geant4 simulation was run to simulate the absorption of muons in different thicknesses of concrete layers and to determine the effect of the material on the energies of muons that were not absorbed. The Geant4 simulation included a simple detector placed directly behind the absorbing material. A Geant4 simulation was also run for the same detector for alpha sources with no absorbing material and the results of this simulation were compared to the signals from the physical detector built in the laboratory and measured using standard alpha sources. The large-statistics simulations using muons of different energies were compared to the predictions of muon absorption from existing literature. The results of the simulations were in good agreement with both the measured signals from the laboratory as well as the predictions from the literature and the general method is found to be well-suited for studies used for muography involving material layers of uniform thickness.
Full article
(This article belongs to the Special Issue Muography, Applications in Cosmic-Ray Muon Imaging)
►▼
Show Figures
Figure 1
Open AccessArticle
Quenching Circuit Discriminator Architecture Impact on a Sub-10 ps FWHM Single-Photon Timing Resolution SPAD
by
, , , , , , and
Instruments 2023, 7(2), 16; https://doi.org/10.3390/instruments7020016 - 09 Apr 2023
Abstract
In the field of radiation instrumentation, there is a desire to reach a sub-10 ps FWHM timing resolution for applications such as time-of-flight positron emission tomography, time-of-flight positron computed tomography and time-resolved calorimetry. One of the key parts of the detection chain for
[...] Read more.
In the field of radiation instrumentation, there is a desire to reach a sub-10 ps FWHM timing resolution for applications such as time-of-flight positron emission tomography, time-of-flight positron computed tomography and time-resolved calorimetry. One of the key parts of the detection chain for these applications is a single-photon detector and, in recent years, the first single-photon avalanche diode (SPAD) with a sub-10 ps timing resolution was presented. To reach such a timing resolution, the SPAD was read out by an operational amplifier operated in open-loop as a comparator. This paper presents a comparison between comparators and inverters to determine which type of leading-edge discriminator can obtain the best single-photon timing resolution. Six different quenching circuits (QCs) implemented in TSMC 65 nm are tested with SPADs of the same architecture and in the same operation conditions. This allows us to compare experimental results between the different QCs. This paper also presents a method to measure the SPAD signal slope, the SPAD excess voltage variation and simulations to determine the added jitter of different leading-edge discriminators. For some discriminator architectures, a cascode transistor was required to increase the maximum excess voltage of the QC. This paper also presents the impact on the single-photon timing resolution of adding a cascode transistor for a comparator or an inverter-based discriminator. This paper reports a 6.3 ps FWHM SPTR for a SPAD read out by a low-threshold comparator and a 6.8 ps FWHM SPTR for an optimized 1 V inverter using a cascode transistor for a higher excess voltage.
Full article
(This article belongs to the Special Issue Feature Papers in Instruments 2021–2022)
►▼
Show Figures
Figure 1
Open AccessArticle
Design and Manufacture of a Test Device for Radiosynthesizer Vacuum Pumps
Instruments 2023, 7(2), 15; https://doi.org/10.3390/instruments7020015 - 06 Apr 2023
Abstract
►▼
Show Figures
Vacuum pump wear is the most prevalent failure mode of the IBA Synthera® automated radiochemistry system. Rebuilding or replacing the pump causes equipment downtime and increases the radiation exposure of the service personnel. We built a dedicated test device to assess new
[...] Read more.
Vacuum pump wear is the most prevalent failure mode of the IBA Synthera® automated radiochemistry system. Rebuilding or replacing the pump causes equipment downtime and increases the radiation exposure of the service personnel. We built a dedicated test device to assess new or rebuilt pumps prior to installation, thus reducing downtime and radiation exposure during repairs. The Testbed incorporates a microprocessor that actuates the pump, valves, and pressure sensor; communicates with the user through lights, buttons, and an alphanumeric screen; and outputs test results to a laptop. The Testbed increases productivity and safety in the radiochemistry laboratory.
Full article
Figure 1
Open AccessProject Report
Fast Timing Detectors and Applications in Cosmic Ray Physics and Medical Science
by
, , , , and
Instruments 2023, 7(2), 14; https://doi.org/10.3390/instruments7020014 - 23 Mar 2023
Abstract
We use fast silicon detectors and the fast sampling method originally developed for high energy physics for two applications: cosmic ray measurements in collaboration with NASA and dose measurements during flash beam cancer treatment. The cosmic ray measurement will benefit from the fast
[...] Read more.
We use fast silicon detectors and the fast sampling method originally developed for high energy physics for two applications: cosmic ray measurements in collaboration with NASA and dose measurements during flash beam cancer treatment. The cosmic ray measurement will benefit from the fast sampling method to measure the Bragg peak where the particle stops in the silicon detector and the dose measurement is performed by counting the number of particles that enter the detector.
Full article
(This article belongs to the Special Issue Timing Detectors)
►▼
Show Figures
Figure 1
Open AccessReview
Cosmic-Ray Tomography for Border Security
by
, , , , , and
Instruments 2023, 7(1), 13; https://doi.org/10.3390/instruments7010013 - 20 Mar 2023
Cited by 2
Abstract
A key task for customs workers is the interception of hazardous, illegal and counterfeit items in order to protect the health and safety of citizens. However, it is estimated that only a small fraction of cargo is inspected and an even smaller fraction
[...] Read more.
A key task for customs workers is the interception of hazardous, illegal and counterfeit items in order to protect the health and safety of citizens. However, it is estimated that only a small fraction of cargo is inspected and an even smaller fraction of trafficked goods are detected. Today, the most widely used technology for scanning vehicles, ranging from vans and trucks to railcars, is ray and X-ray radiography. New technologies are required to overcome current technological shortcomings, such as the inability to detect the target material composition, the usage of harmful ionising radiation sources and the resultant low throughput. Cosmic ray tomography (CRT) is a promising technology for cargo screening. Cosmic ray muons have average energies of around 10,000 times larger than a typical X-ray and therefore can penetrate relatively large and dense materials. By analysing muon scattering, it is possible to identify materials hidden inside shielding that is too thick or deep for other imaging methods. CRT is also completely passive, exploiting naturally occurring secondary cosmic radiation, and is therefore safe for humans and animals. Contrary to conventional X-ray- or -ray-based imaging techniques, CRT also allows material differentiation and anomaly localisation within the cargo or vehicle through the provision of 3D images. This article reviews the current state-of-the-art technology in CRT, critically assessing the strengths and weaknesses of the method, and suggesting further directions for development.
Full article
(This article belongs to the Special Issue Muography, Applications in Cosmic-Ray Muon Imaging)
►▼
Show Figures
Figure 1
Open AccessArticle
Upgrade of Thomson Scattering Diagnostic on HL-2A
by
, , , , , , , , and
Instruments 2023, 7(1), 12; https://doi.org/10.3390/instruments7010012 - 06 Mar 2023
Abstract
The Thomson scattering diagnostic of the HL-2A tokamak device was upgraded to improve its multi-point diagnostic capability, including new collection optics, fibers bundles, and data analysis code. The small old collection lens was replaced by a six-piece lens with a Cooke optical design.
[...] Read more.
The Thomson scattering diagnostic of the HL-2A tokamak device was upgraded to improve its multi-point diagnostic capability, including new collection optics, fibers bundles, and data analysis code. The small old collection lens was replaced by a six-piece lens with a Cooke optical design. The aperture of its first standard sphere face is 310.125 mm, which successfully increases the amount of collected scattering light by about three times. The new collection optic module allows for up to twenty-six spatial points. A kind of Y-type fiber bundle has also been used to ensure that the fiber end-face matches the image of the laser beam exactly. Additionally, the new data analysis code can provide preview results in seconds. Finally, the multi-point diagnostic ability has been significantly improved.
Full article
(This article belongs to the Special Issue Feature Papers in Instruments 2021–2022)
►▼
Show Figures
Figure 1
Open AccessArticle
Commissioning Results of the New Compact ECR Ion Source for Electrostatic Storage Ring at KACST
Instruments 2023, 7(1), 11; https://doi.org/10.3390/instruments7010011 - 23 Feb 2023
Abstract
►▼
Show Figures
A compact microwave ECR ion source with low operating power was tested and commissioned for the ion injector line in the multipurpose low-energy ELASR storage ring facility at King Abdulaziz City for Science and Technology (KACST) in Riyadh. The compact ECR ion source
[...] Read more.
A compact microwave ECR ion source with low operating power was tested and commissioned for the ion injector line in the multipurpose low-energy ELASR storage ring facility at King Abdulaziz City for Science and Technology (KACST) in Riyadh. The compact ECR ion source can deliver singly charged ions with an energy of up to 50 keV and a beam current of up to 50 μA or up to 500 µA with a larger extraction aperture. The plasma in the ECR chamber is driven by a simple transmitter antenna, making the overall size of the ion source only 6 cm in diameter, which is relatively small when compared with other ECR systems. Additionally, the source operates without a high-voltage platform, which significantly reduces the overall footprint and simplifies the system operation. In this paper, the mechanical design and modeling of the ECR ion source are introduced, and the layout of the first part of the beam line is presented along with the numerical simulation results. In addition, the experimental results obtained for the first generated ion beam and commissioning of the ECR ion source are introduced and discussed.
Full article
Figure 1
Open AccessArticle
RF Design and Measurements of a C-Band Prototype Structure for an Ultra-High Dose-Rate Medical Linac
by
, , , , , , , , and
Instruments 2023, 7(1), 10; https://doi.org/10.3390/instruments7010010 - 22 Feb 2023
Abstract
In this paper, we illustrate the RF design and measurements of a C-band prototype structure for an Ultra High Dose Rate medical linac. (1) Background: FLASH Radiotherapy (RT) is a revolutionary new technique for cancer cure. It releases ultra-high radiation dose rates (above
[...] Read more.
In this paper, we illustrate the RF design and measurements of a C-band prototype structure for an Ultra High Dose Rate medical linac. (1) Background: FLASH Radiotherapy (RT) is a revolutionary new technique for cancer cure. It releases ultra-high radiation dose rates (above 100 Gy/s) in microsecond short pulses. In order to obtain a high dose in a very short time, accelerators with high-intensity currents (the order of 100 mA peak currents) have to be developed. In this contest, Sapienza University, in collaboration with SIT-Sordina IORT Technology spa, is developing a new C-band linac to achieve the FLASH regime. (2) Methods: We performed the RF electromagnetic design of the prototype of the C band linac using CST STUDIO Suite Code and the RF low power RF test at Sapienza University of Rome. The measurements of the field in the cavity have been done with the bead-pull technique. (3) Results: This device is a nine-cell structure operating on the mode at 5.712 GHz (C-band). We report and discuss the test measurement results on a full-scale copper prototype, showing good agreement with CST RF simulations. A tuning procedure has been implemented in order to ensure proper operating frequency and to reach a field profile flatness of the order of a few percent. (4) Conclusions: The prototype of a C-band linac for FLASH applications was successfully tested with low RF power at Sapienza University. The fabrication and ad hoc tuning procedures have been optimized and discussed in the paper.
Full article
(This article belongs to the Special Issue Microwave Measurements, Methods and Instruments for Science, Society and Industry)
►▼
Show Figures
Figure 1
Open AccessArticle
A Beam Monitor for Ion Beam Therapy Based on HV-CMOS Pixel Detectors
by
, , , , , , , , , , , , , , and
Instruments 2023, 7(1), 9; https://doi.org/10.3390/instruments7010009 - 09 Feb 2023
Abstract
Particle therapy is a well established clinical treatment of tumors. More than one hundred particle therapy centers are in operation world-wide. The advantage of using hadrons like protons or carbon ions as particles for tumor irradiation is the distinct peak in the depth-dependent
[...] Read more.
Particle therapy is a well established clinical treatment of tumors. More than one hundred particle therapy centers are in operation world-wide. The advantage of using hadrons like protons or carbon ions as particles for tumor irradiation is the distinct peak in the depth-dependent energy deposition, which can be exploited to accurately deposit doses in the tumor cells. To guarantee this, high accuracy in monitoring and control of the particle beam is of the utmost importance. Before the particle beam enters the patient, it traverses a monitoring system which has to give fast feedback to the beam control system on position and dose rate of the beam while minimally interacting with the beam. The multi-wire chambers mostly used as beam position monitors have their limitations when a fast response time is required (drift time). Future developments such as MRI-guided ion beam therapy pose additional challenges for the beam monitoring system, such as tolerance of magnetic fields and acoustic noise (vibrations). Solid-state detectors promise to overcome these limitations and the higher resolution they offer can create additional benefits. This article presents the evaluation of an HV-CMOS detector for beam monitoring, provides results from feasibility studies in a therapeutic beam, and summarizes the concepts towards the final large-scale assembly and readout system.
Full article
(This article belongs to the Special Issue Medical Applications of Particle Physics)
►▼
Show Figures
Figure 1
Open AccessArticle
A Non-Inductive Magnetic Eye-Tracker: From Dipole Tracking to Gaze Retrieval
by
and
Instruments 2023, 7(1), 8; https://doi.org/10.3390/instruments7010008 - 07 Feb 2023
Abstract
►▼
Show Figures
We analyze the information that can be retrieved from the tracking parameters produced by an innovative wearable eye tracker. The latter is based on a permanent-magnet marked corneal lens and by an array of magnetoresistive detectors that measure the magnetostatic field in several
[...] Read more.
We analyze the information that can be retrieved from the tracking parameters produced by an innovative wearable eye tracker. The latter is based on a permanent-magnet marked corneal lens and by an array of magnetoresistive detectors that measure the magnetostatic field in several positions in the eye proximity. We demonstrate that, despite missing information due to the axial symmetry of the measured field, physiological constraints or measurement conditions make possible to infer complete eye-pose data. Angular precision and accuracy achieved with the current prototypical device are also assessed and briefly discussed. The results show that the instrumentation considered is suitable as a new, moderately invasive medical diagnostics for the characterization of ocular movements and associated disorders.
Full article
Figure 1
Open AccessArticle
Characterization and On-Field Performance of the MuTe Silicon Photomultipliers
Instruments 2023, 7(1), 7; https://doi.org/10.3390/instruments7010007 - 22 Jan 2023
Abstract
The Muon Telescope, MuTe, is an instrument for imaging volcanoes in Colombia. It consists of a scintillator tracking system and a water Cherenkov detector for particle energy measurement. The Muon Telescope operates autonomously in high-altitude environments where the temperature gradient reaches up to
[...] Read more.
The Muon Telescope, MuTe, is an instrument for imaging volcanoes in Colombia. It consists of a scintillator tracking system and a water Cherenkov detector for particle energy measurement. The Muon Telescope operates autonomously in high-altitude environments where the temperature gradient reaches up to 10 °C. In this work, we characterize the telescope silicon photomultipliers’ breakdown voltage, gain, and noise for temperature variations spanning 0 to 40 °C. We demonstrate that the discrimination threshold for the Muon Telescope hodoscope must be above 5 photo-electrons to avoid contamination due to dark count, crosstalk, and afterpulsing. We also assess the detector counting rate depending on day-night temperature variations.
Full article
(This article belongs to the Special Issue Muography, Applications in Cosmic-Ray Muon Imaging)
►▼
Show Figures
Figure 1
Open AccessEditorial
Acknowledgment to the Reviewers of Instruments in 2022
Instruments 2023, 7(1), 6; https://doi.org/10.3390/instruments7010006 - 18 Jan 2023
Abstract
High-quality academic publishing is built on rigorous peer review [...]
Full article
Open AccessArticle
A Cross-Line Structured Light Scanning System Based on a Measuring Arm
Instruments 2023, 7(1), 5; https://doi.org/10.3390/instruments7010005 - 03 Jan 2023
Cited by 1
Abstract
The measurement system proposed in this paper, using a measuring arm and line structured light, has a wide range of applications. To improve the scanning efficiency, the system outlined in this paper uses two single-line structured lights to form crosshair structured light, which
[...] Read more.
The measurement system proposed in this paper, using a measuring arm and line structured light, has a wide range of applications. To improve the scanning efficiency, the system outlined in this paper uses two single-line structured lights to form crosshair structured light, which we combine with a measuring arm to form a comprehensive scanning measurement system. The calibration method of Zhengyou Zhang and a calibration board are used to complete parameter calibration of the sensors and cameras, as well as hand–eye calibration of the measuring arm. For complex curved-surface objects, this system extracts the cross-line structured light optical center location, which suffers from ambiguity. Therefore, we introduce the use of periodic control of the two line structured light sources in order to resolve the light extraction polysemy. Our experimental results indicate that the proposed system can effectively satisfy the function of crosshair structured light scanning of large, complex surfaces.
Full article
(This article belongs to the Special Issue Photonic Devices Instrumentation and Applications II)
►▼
Show Figures
Figure 1
Highly Accessed Articles
Latest Books
E-Mail Alert
News
Topics
Conferences
Special Issues
Special Issue in
Instruments
Selected Papers from the Workshop on Physics and Applications of High Brightness Beams
Guest Editors: Mario Galletti, Alessandro CianchiDeadline: 1 September 2023
Special Issue in
Instruments
Printed Devices for Industrial and Medical IoT
Guest Editors: Michela Borghetti, Mauro SerpelloniDeadline: 30 September 2023
Special Issue in
Instruments
Advances in Space AstroParticle Physics: Frontier Technologies for Particle Measurements in Space
Guest Editors: Valerio Vagelli, Matteo DurantiDeadline: 15 October 2023
Special Issue in
Instruments
Medical Applications of Particle Physics
Guest Editor: Ivor FleckDeadline: 31 October 2023
Topical Collections
Topical Collection in
Instruments
Selected Papers from Instruments’ Editorial Board Members
Collection Editor: Antonio Ereditato